Part Number Hot Search : 
FN3376 RAC324D 385213 Z1031 D3100 EA0520N ARA1400I KDV149D
Product Description
Full Text Search
 

To Download PPS-125-33 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 125W Single Output with PFC Function
Features :
PPS-125
series
Universal AC input / Full range Built-in active PFC function Protections: Short circuit / Overload / Over voltage PWM control and regulated High power density 6.117W/inch3 Built-in remote sense function LED indicator for power on 100% full load burn-in test 125W with 18CFM FAN 5"x3" compact size 3 years warranty
SPECIFICATION
MODEL DC VOLTAGE RATED CURRENT PPS-125-3.3 3.3V 20A PPS-125-5 5V 20A 0 ~ 20A 0 ~ 25A 100W 125W 100mVp-p 4.75 ~ 5.25V 2.0% 0.5% 1.0% PPS-125-12 12V 8.5A 0 ~ 8.5A 0 ~ 10.5A 102W 126W 100mVp-p PPS-125-13.5 PPS-125-15 13.5V 7.5A 0 ~ 7.5A 0 ~ 9.3A 101.25W 125.55W 100mVp-p 15V 6.7A 0 ~ 6.7A 0 ~ 8.4A 100.5W 126W 100mVp-p PPS-125-24 24V 4.2A 0 ~ 4.2A 0 ~ 5.2A 100.8W 124.8W 150mVp-p PPS-125-27 27V 3.8A 0 ~ 3.8A 0 ~ 4.6A 102.6W 124.2W 150mVp-p PPS-125-48 48V 2.1A 0 ~ 2.1A 0 ~ 2.6A 100.8W 124.8W 250mVp-p
CURRENT RANGE (convection) 0 ~ 20A CURRENT RANGE (18CFM FAN) 0 ~ 25A RATED POWER (convection) 66W RATED POWER (18CFM FAN) 82.5W OUTPUT RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) 115VAC 230VAC INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & EMC
(Note 4)
3.13 ~ 3.46V 2.0% 0.5% 1.0% 24ms/230VAC 90 ~ 264VAC 47~63Hz
11.40 ~ 12.60V 12.82 ~ 14.17V 14.25 ~ 15.75V 22.80 ~ 25.20V 25.65 ~ 28.35V 45.60 ~ 50.40V 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 0.5% 1.0% 0.5% 1.0% 0.5% 1.0% 0.5% 1.0% 0.5% 1.0% 0.5% 1.0%
1000ms, 30ms/230VAC
2000ms, 30ms/115VAC at full load
24ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 80% 80% 80% 83% 83% 84%
PF>0.93/230VAC 70% 1.2A 79% 1.7A
0.6A 0.75A COLD START 24A/230VAC <2mA / 240VAC 130 ~ 160% rated output power Protection type : Fold back current limiting, recovers automatically after fault condition is removed 3.63 ~ 4.45V 5.5 ~ 6.75V 13.8 ~ 16.2V 15.5 ~ 20.25V 17.25 ~ 20.25V 27.6 ~ 32.4V 31.05 ~ 36.45V 57.6 ~ 67.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed -20 ~ +70 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -40 ~ +85 , 10 ~ 95% RH 0.05%/ (0 ~ 50 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B HARMONIC CURRENT Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A EMS IMMUNITY MTBF 111.7Khrs min. MIL-HDBK-217F (25 ) DIMENSION PACKING 127*76.2*34.6mm (L*W*H) 0.37Kg; 36pcs/14.3Kg/0.79CUFT
ISOLATION RESISTANCE
OTHERS
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Heat Sink HS1,HS2 & HS3 can not be shorted.
File Name:PPS-125-SPEC 2008-10-22
125W Single Output with PFC Function
Mechanical Specification
127 5 115.6
PPS-125
series
Unit:mm
6.4
HS3 SVR1 HS1 LED1 1 CN3 2 1 2 3 4 5 6 7 8 CN5
76.2
64.8
FS1 T2A 250VAC
1 2 3 CN1
HS2
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No. 1 2 3 Assignment AC/L No Pin AC/N Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
DC Output Connector (CN5) : JST B8P-VH or equivalent
Pin No. 1~4 5~8 Assignment -V +V Mating Housing JST VHR or equivalent Terminal JST SVH-21T-P1.1 or equivalent
5
43.
Air flow direction
Remote Sense(CN3) : Molex 5045-02 or equivalent
Pin No. 1 2 Assignment RS+ RS34.6
Mating Housing Molex 5051 or equivalent
Terminal Molex 4809 or equivalent
HS1, HS2 & HS3 can not be shorted
3max.
Block Diagram
EMI FILTER & RECTIFIERS
fosc : 100KHz
I/P
PFC CIRCUIT
POWER SWITCHING
RECTIFIERS & FILTER FEEDBACK DETECTION CIRCUIT O.V.P.
+V -V
FG
O.L.P.
PWM & PFC CONTROL
Derating Curve
Output Derating VS Input Voltage
125
100
Forced air 18CFM
100
90 80 70
Free air Convection
70
LOAD (%)
50
LOAD(%)
0 10 20 25 30 40 50 60 70 (HORIZONTAL)
60 50 40
20
-20
90
100
115
135
155
264
AMBIENT TEMPERATURE ( )
INPUT VOLTAGE (V) 60Hz
File Name:PPS-125-SPEC 2008-10-22


▲Up To Search▲   

 
Price & Availability of PPS-125-33

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X